SKU: GJL1211901R8104
VB6-30-10-84
In stock
₴ 3 771,90
The VB6-30-10 mini reversing contactor is a compact 3 pole contactor with 1 auxiliary contact, screw terminals and normal mechanical interlock. They are ideally suited for applications where reliability is a must and space is at a premium. Mini reversing contactors are used in residential buldings, commercial buildings and industrial applications for the control of three-phase motor loads up to 4 kW (AC-3). Further features are the silent coil, a switch position indication and the integrated possibility for rail or wall mounting.
Characteristics
Customs Tariff Number
85365080
Brand
ABB Stotz-Kontakt GmbH, ABB Stotz-Kontakt GmbH
Minimum Order Quantity
1 piece
Product Net Weight
0.355 kg
Package Level 1 Units
5 piece
Package Level 1 Depth / Length
280 mm
Package Level 1 Height
54 mm
Package Level 1 Width
115 mm
Package Level 1 Gross Weight
1.845 kg
Declaration of Conformity - CE
1SAD938517-0001
RoHS Information
1SAD938517-0001
RoHS Status
Following EU Directive 2011/65/EU
ETIM 7
EC000010 - Combination of contactors
Degree of Protection
Auxiliary Circuit Terminals IP20/Control Circuit Terminals IP20/Main Circuit Terminals IP20
Instructions and Manuals
2CDC102046M6801
Dimension Diagram
GJL1200447F0001
Product Net Width
96.5 mm
Product Net Height
57.5 mm
Product Net Depth / Length
46.5 mm
Rated Operational Voltage
Auxiliary Circuit 690 V AC/Auxiliary Circuit 250 V DC/Main Circuit 690 V AC/Main Circuit 220 V DC
Rated Frequency (f)
Control Circuit 400 Hz/Control Circuit 50 Hz/Control Circuit 60 Hz/Main Circuit 60 Hz/Main Circuit 50 Hz/Main Circuit DC
Rated Insulation Voltage (Ui)
690 V/acc. to UL/CSA 600 V
Number of Poles
3
Pollution Degree
3
Tightening Torque
Control Circuit 0.8 ... 1.1 N·m/Main Circuit 0.8 ... 1.1 N·m
Wire Stripping Length
Auxiliary Circuit 9 mm/Main Circuit 9 mm
Power Loss
at Rated Operating Conditions per Pole 2 W
Standards
IEC/EN 60947-1/IEC/EN 60947-4-1/IEC/EN 60947-5-1/UL 60947-1/UL 60947-4-1
Tightening Torque UL/CSA
Auxiliary Circuit 7 in·lb/Control Circuit 7 in·lb/Main Circuit 7 in·lb
Ambient Air Temperature
Operation -20 ... +55 °C/Storage -40 ... +80 °C
CB Certificate
1SAA938000-2002
CQC Certificate
CQC2003010304064033
DNV GL Certificate
1SAA938000-0306
EAC Certificate
1SAA920000-2702
Environmental Information
1SAC200067H0009
RMRS Certificate
1SAA938000-0704
Package Level 1 EAN
4013614413797
Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000010 - Starter combination
ETIM 6
EC000010 - Combination of contactors
eClass
V11.0 : 27371009
UNSPSC
39121529
Mechanical Durability
10000000 cycle
Number of Main Contacts NO
3
Number of Main Contacts NC
0
General Use Rating UL/CSA
(300 V AC) 12 A
KC Certificate
1SAA938000-1501
Horsepower Rating UL/CSA
(115 V AC) Single Phase 0.25 Hp/(200 V AC) Three Phase 1 Hp/(220 ... 240 V AC) Three Phase 2 Hp/(230 V AC) Single Phase 0.5 Hp/(440 ... 480 V AC) Three Phase 3 Hp/(550 ... 600 V AC) Three Phase 1 Hp
Minimum Switching Capacity
Auxiliary Circuit 17 V/Auxiliary Circuit 5 mA
cULus Certificate
cUL_E191658
Coil Operating Limits
(acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)/(acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Mounting on DIN Rail
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715/TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Full Load Amps Motor Use
(115 V AC) Single Phase 5.8 A/(200 V AC) Three Phase 4.8 A/(220 ... 240 V AC) Three Phase 6.8 A/(230 V AC) Single Phase 4.9 A/(440 ... 480 V AC) Three Phase 4.8 A/(550 ... 600 V AC) Three Phase 1.7 A
Reviews
Description
CAD outline drawing
Certificate
- CQC Certificate, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
- EAC Certificate - B6, BC6, B6S, VB6,B7, BC7, B7D, B7S, VB7, TBC7, ESB24, EN24, ESB40, EN40, ESB63 - Contactors
- CB Certificate - B6, BC6, VB6, VBC6, B7, BC7, VB7, VBC7 - Mini Contactor
- RMRS Certificate - B6, BC6, B7, BC7, VB6, VBC6, VB7, VBC7 - Mini Contactor
Circuit diagram
Declaration of conformity
- UK Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
- CCC Declaration of Conformity, AC Contactor, B6,BC6,B7,BC7,VB6,VBC6,VB7,VBC7, Made in Germany
- EU Declaration of Conformity - B6, B7, K6, VB6, VB7, TBC7, TKC6 - Mini Contactor
Drawing
- Drilling pattern - Mini Reversing Contactor VB6 / VB6A / VBC6 / VBC6A / VB7 / VB7A / VBC7 / VBC7A
- Dimension Drawing - Mini Reversing Contactor VB6 / VB6A / VBC6 / VBC6A / VB7 / VB7A / VBC7 / VBC7A + CAF6
- Drilling pattern - Mini Reversing Contactor VB6 / VB6A / VBC6 / VBC6A / VB7 / VB7A / VBC7 / VBC7A
- Dimension Drawing - Mini Reversing Contactor VB6 / VB6A / VBC6 / VBC6A / VB7 / VB7A / VBC7 / VBC7A
- Dimension Drawing - Mini Reversing Contactor VB6 / VB6A / VBC6 / VBC6A / VB7 / VB7A / VBC7 / VBC7A (-F)
- Dimension Drawing - Mini Reversing Contactor VB6 / VB6A / VBC6 / VBC6A / VB7 / VB7A / VBC7 / VBC7A (-P)
- Dimension Drawing - Mini Reversing Contactor VB6_VBC6_VB7_VBC7_(A) (.dxf)
- Dimension Drawing - Mini Reversing Contactor VB6_VBC6_VB7_VBC7_(A)_(-F) (.dxf)
- Dimension Drawing - Mini Reversing Contactor VB6_VBC6_VB7_VBC7_(A)_(-P) (.dxf)
- Dimension Drawing - Mini Reversing Contactor VB6 / VB7 / VBC6 / VBC7 with Thermal Overload Relay T16
Operating instruction
Reviews
There are no reviews yet.



There are no reviews yet.