SKU: 1SDA059896R1
E3/EWFP3p750VDCVR-VRnew
In stock
₴ 253 332,37
SACE EMAX FIXED PART FOR C.BREAKER E3/E 750V DC THREE-POLE WHIT UPPER TERMINALS VERTICAL AND LOWER TERMINALS VERTICAL NEW
Characteristics
EAN
8015644623203/8015644609139
Brand
ABB S.p.A. Electrification, ABB S.p.A. Electrification
Customs Tariff Number
85389099
Minimum Order Quantity
1 piece
Product Net Weight
37 kg
Package Level 1 Units
1 piece
Package Level 1 Gross Weight
40 kg
Declaration of Conformity - CE
1SDL000165R0015
ETIM 7
EC002043 - Chassis part power circuit breaker
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Instructions and Manuals
1SDH000635R0002
Product Net Width
432 mm
Product Net Height
461 mm
Product Net Depth / Length
396.5 mm
Number of Poles
3
Standards
IEC
Environmental Information
1SDL000142R0
Package Level 1 EAN
8015644609139
Object Classification Code
Q
ETIM 4
EC000228 - Power circuit-breaker for trafo/generator/installation prot.
ETIM 5
EC000228 - Power circuit-breaker for trafo/generator/installation prot.
ETIM 6
EC002043 - Chassis part power circuit breaker
Current Type
DC
Product Main Type
SACE Emax
Product Name
Fixed Part
Product Type
Fixed Part
Rated Voltage (Ur)
750 V
Sub-type
E3
Terminal Connection Type
Withdrawable Circuit-Breakers/Rear flat Vertical
Version
WFP
Reviews
Description
- Brochure ATS021, ATS022 - Automatic Transfer Switches
- Panorama of the Low Voltage Apparatus - Automatic moulded-case and air circuit-breakers
- SACE Tmax VF and Emax VF variable frequency applications
- Emax power circuit breakers. The evolution continues. 200 kA Fuseless
- Emax air circuit-breakers. The evolution continues.
- New Emax. The evolution continues. (English - German)
Catalogue
- ABB SACE LTT -40 °C circuit-breakers. Special version for low temperature environments
- New Emax - Low voltage air circuit-breakers
- SACE Tmax VF and Emax VF variable frequency applications
- Emax UL - Low voltage power circuit breakers
- New Emax - Low voltage power circuit breakers (UL version)
Certificate
- CQC Certificate, Switch-disconnector, E3H/E MS, E3S MS, Made in Italy
- CQC Certificate, Air Circuit-breaker, E3H VF, Made in Italy
- CQC Certificate, Air Circuit-breaker, E3N/E, E3H/E, Made in Italy
- CQC Certificate, Air circuit-breaker, E3N,E3S,E3H,E3V,E3H-A, Made in Italy
- CQC Certificate, Switch-Disconnector, E3H/E MS, Made in China
- CQC Certificate, Switch-Disconnector, E3N/MS,E3S/MS,E3V/MS, Made in China
- CQC Certificate, Switch-Disconnector, E3N/MS,E3S/MS,E3V/MS, Made in China
- CQC Certificate, Air Circuit Breaker, E3N,E3S,E3H,E3V,E3H/E, Made in China
- CQC Certificate, Air Circuit Breaker, E3N/E,E3H/E, Made in China
Circuit diagram
Data sheet
- Emax E3 - Canadian Version
- E3 3200A Fixed and Drawout Emax Air Circuit Breakers -- IEC
- Emax E3 Data Sheet
Declaration of conformity
- CCC Declaration of Conformity, Air Circuit-breaker, E3H VF, Made in Italy
- CCC Declaration of Conformity, Air Circuit-breaker, E3N/E, E3H/E, Made in Italy
- CCC Declaration of Conformity, Switch-disconnector, E3H/E MS, E3S MS, Made in Italy
- CCC Declaration of Conformity, Air Circuit Breaker, E3N,E3S,E3H,E3V,E3H/E, Made in China
- CCC Declaration of Conformity, Air Circuit Breaker, E3N/E,E3H/E, Made in China
- CCC Declaration of Conformity, Switch-Disconnector, E3H/E MS, Made in China
- CCC Declaration of Conformity, Switch-Disconnector, E3H/EMS, Made in China
- CCC Declaration of Conformity, Switch-Disconnector, E3N/MS,E3S/MS,E3V/MS, Made in China
- EC Declaration of Conformity Emax E3
- CE Conformity Declaration Emax DC E3/E
Drawing
- E3 2500A four poles withdrawable UL vert terminals
- E3 2500A three poles withdrawable UL vert terminals
- E3 four poles fixed IEC UL horiz terminals
- E3 four poles fixed IEC vert terminals
- E3 four poles fixed UL vert terminals
- E3 four poles withdrawable IEC horiz terminals
- E3 four poles withdrawable IEC vert terminals
- E3 four poles withdrawable UL horiz terminals
- E3 four poles withdrawable UL vert terminals
- E3 three poles fixed IEC UL horiz terminals
- E3 three poles fixed IEC vert terminals
- E3 three poles fixed UL vert terminals
- E3 three poles withdrawable IEC horiz terminals
- E3 three poles withdrawable IEC vert terminals
- E3 three poles withdrawable UL horiz terminals
- E3 three poles withdrawable UL vert terminals
- E3 DC fixed 3p rear terminals
- E3 DC fixed 4p rear terminals
- E3 DC withdrawable 3p rear terminals
- E3 DC withdrawable 4p rear terminals
- E3X-A fixed 3p rear vertical terminals
- E3X-A fixed 4p rear vertical terminals
- E3X-A withdrawable 3p rear vertical terminals 1600-2000A
- E3X-A withdrawable 3p rear vertical terminals 800-1000-1200A
- E3X-A withdrawable 4p rear vertical terminals 1600-2000A
- E1-E6 Fixed version Front terminals
- E1-E6 Fixed version Vertical rear terminals
- E1-E6 Withdrawable version Flat terminals
- E1-E6 Withdrawable version Front terminals
- E1-E6 Withdrawable version Vertical rear terminals
- E1-E6-A ANSI Fixed version Vertical rear terminals
- E3 3p Fixed version Horizontal rear terminals
- E3 3p Withdrawable version Horizontal rear terminals
- E3 4p Fixed version Horizontal rear terminals
- E3 4p Withdrawable version Horizontal rear terminals
- E3-A 3p Withdrawable version Vertical rear terminals
- E3-A ANSI 3p Fixed version Horizontal rear terminals
- E3-A ANSI 3p Withdrawable version Horizontal rear terminals
- E3-A ANSI 3p Withdrawable version Vertical rear terminals
- E3-A ANSI 3p Withdrawable version Vertical rear terminals
- E3-A ANSI 4p Fixed version Horizontal rear terminals
- E3-A ANSI 4p Withdrawable version Horizontal rear terminals
- E3-A ANSI 4p Withdrawable version Vertical rear terminals
- E3-A ANSI 4p Withdrawable version Vertical rear terminals
- E3-A ANSI 4p Withdrawable version Vertical rear terminals
Environmental product declaration
Instruction
Leaflet
Manual
- Modbus System Interface
- Installation, service and maintenance instructions for low voltage air circuit-breakers Emax
- Vertical terminals for fixed circuit-breakers
- Conversion kit for fixed part terminals from vertical to horizontal
- UL Listed - Installation, service and maintenance instructions for low voltage air circuit-breakers
- UL Listed - Installation, service and maintenance instructions for the fixed part of withdrawable version circuit-breakers
- Installation and service instructions Emax VF
- Installation and service instructions Emax VF/UL
- Installation and service instructions for the fixed part
- PR122DC-PR123DC Modbus System Interface
- PR122VF Modbus System Interface
- Terminal Block
- Conversion kit for fixed part terminals from horizontal to vertical
- Conversion to fixed part
- Front terminals for fixed circuit-breakers
- Horizontal terminals for E4 and fixed E6
- Instruction for installation of EMAX DC
- SACE PR121 microprocessor-based electronic release
- SACE PR122 microprocessor-based electronic release
- SACE PR123 microprocessor-based electronic release
Product guide
- Product note Fault protection of LVDC microgrids
- White Paper - ABB solutions for switching and protection of low speed wind turbines
- Technical Application Papers No.1 - Low voltage selectivity with ABB circuit-breakers
- White Paper - Directional protection and directional zone selectivity
- White Paper - Double Ground Fault Protection . Implementation
- White Paper - Integration between the MV protection and control unit REF542 and the LV protection trip unit PR123: selectivity and earth fault
- White Paper - Working with the Trip Characteristic Curves of ABB SACE Low Voltage Circuit-Breakers
- Technical Application Papers No.2 - MV/LV transformer substations: theory and examples of short-circuit calculation
- Technical Application Papers No.3 - Distribution systems and protection against indirect contact and earth fault
- Technical Application Papers No.4 - ABB circuit breakers inside LV switchboards
- Technical Application Papers No.8 - Power factor correction and harmonic filtering in electrical plants
- Electrical installation handbook - Protection, control and electrical devices - 6th edition
Software
- ABB SACE Emax DC Configuration Tool
- Migration Converter SACE Tmax T vs SACE Tmax XT EN
- PR010 - SD Test Unit Interface - Software for PC v. 7.8
Technical publication
- Technical Application Papers No.14 Faults in LVDC microgrids with front-end converters
- Technical Application Papers No.12 - Generalities on naval systems and installations on board
- Technical Application Papers No.13 - Wind power plants
- Technical Application Papers No.5 - ABB circuit-breakers for direct current applications
- Low Voltage Circuit Breakers - Working with trip characteristic curves
Technical specification
White paper
Reviews
There are no reviews yet.





There are no reviews yet.