SKU: 1SAZ721201R1051
TF42-24
In stock
₴ 3 460,20
The TF42-24 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
Characteristics
Customs Tariff Number
85364900
Brand
ABB Stotz-Kontakt GmbH, ABB Stotz-Kontakt GmbH
Minimum Order Quantity
1 piece
Product Net Weight
0.145 kg
Package Level 1 Units
carton 1 piece
Package Level 1 Depth / Length
78 mm
Package Level 1 Height
92 mm
Package Level 1 Width
48 mm
Package Level 1 Gross Weight
0.16 kg
Package Level 2 Units
carton 40 piece
Package Level 2 Depth / Length
395 mm
Package Level 2 Height
210 mm
Package Level 2 Width
280 mm
Package Level 2 Gross Weight
8.066 kg
Declaration of Conformity - CE
1SAD938511-0181
RoHS Information
1SAD938508-0181
RoHS Status
Following EU Directive 2011/65/EU
ETIM 7
EC000106 - Thermal overload relay
Degree of Protection
IP20
Instructions and Manuals
2CDC106022M6802
Dimension Diagram
1SAZ700405F0001
Product Net Width
45 mm
Product Net Height
88.3 mm
Product Net Depth / Length
70.5 mm
Setting Range
20 ... 24 A
Rated Operational Voltage
Auxiliary Circuit 600 V AC/DC/Main Circuit 690 V AC/Main Circuit 600 V DC
Rated Operational Current (Ie)
24 A
Rated Frequency (f)
Auxiliary Circuit 50 Hz/Auxiliary Circuit 60 Hz/Auxiliary Circuit DC/Main Circuit 50 Hz/Main Circuit 60 Hz
Rated Insulation Voltage (Ui)
690 V
Number of Poles
3
Number of Protected Poles
3
Pollution Degree
3
Tightening Torque
Auxiliary Circuit 1 ... 1.5 N·m/Main Circuit 2.5 ... 2.7 N·m
Wire Stripping Length
Auxiliary Circuit 9 mm/Main Circuit 12 mm
Recommended Screw Driver
Main Circuit Pozidriv 2
Power Loss
at Rated Operating Conditions per Pole 1.8 W
Suitable For
AF09/AF12/AF16/AF26/AF30/AF38
Standards
IEC/EN 60947-1/IEC/EN 60947-4-1/IEC/EN 60947-5-1/UL 60947-1/UL 60947-4-1
Ampere Rating UL/CSA
24 A
Contact Rating UL/CSA
(NC:) B600/(NC:) Q600/(NO:) Q600/(NO:) D300
Tightening Torque UL/CSA
Auxiliary Circuit 9 ... 13 in·lb/Main Circuit 22 in·lb
Ambient Air Temperature
Operation -25 ... +60 °C/Operation Compensated -25 ... +60 °C/Storage -50 ... +80 °C
ABS Certificate
1SAA941001-0102
BV Certificate
1SAA941001-0203
CB Certificate
1SAA941009-2001
CQC Certificate
CQC2011010309464423
cUL Certificate
1SAA941001-1702
DNV GL Certificate
1SAA941001-0302
EAC Certificate
1SAA941002-2701
Environmental Information
1SAC200057H0009
GL Certificate
1SAA941007-0401/1SAA941001-0302
LR Certificate
1SAA941001-0502
RINA Certificate
1SAA941000-0802
RMRS Certificate
1SAA941000-0704
UL Certificate
cUL_E48139/1SAA941001-1702
Package Level 1 EAN
4013614398155
Package Level 2 EAN
4013614440205
Object Classification Code
F
ETIM 4
EC000106 - Thermal overload relay
ETIM 5
EC000106 - Thermal overload relay
ETIM 6
EC000106 - Thermal overload relay
eClass
V11.0 : 27371501
UNSPSC
39121520
E-Number (Finland)
3706129
E-Number (Sweden)
3211973
ATEX Certificate
1SAA941001-3901
cUR Certificate
cUL_E48139
IECEx Certificate
1SAA941003-4001
Reviews
Description
Brochure
CAD outline drawing
Catalogue
- 1SBC100195C0203 - Short-form catalog Motor protection and control: Manual motor starters, contactors and overload relays (PDF) - Edition Nov 2016
- Motor control and protection for Rolling stock application
- Motor control and protection for Rolling stock application_PDF
- 1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition march 2020
Certificate
- IECEx Certificate - TF42 - Manual Motor Starter
- ABS Certificate - T16, TF42 - Thermal Overload Relays
- ATEX Certificate - TF42 - Thermal Overload Relay
- LR Certificate - T16, TF42 - Thermal Overload Relays
- DNV-GL Certificate - T16, TF42- Thermal Overload Relays
- EAC Certificate - TA25DU, TA42DU, TA75DU, TA85DU, TA110DU, TA200DU, T16, TF42, TF65, TF96, TF140DU - Overload Relays
- RMRS Certificate - T16, TF42, T7DU, TA25DU, TA42DU, TA75DU, TA80DU, TA110DU, TA200DU,TA450DU, TA450SU, T900DU, T900SU - Overload Relays
- Rina Certificate - T16, TF42 - Thermal Overload Relays
- BV Certificate - T16, TF42, TF65, TF96 - Thermal Overload Relays
- UL Certificate of Compliance - T16, TF42
- CQC Certificate, Thermal Overload Relay, TF42, TF42B, Made in Germany
- cUL E48139
- CB Certificate - TF42- Thermal Overload Relays
Circuit diagram
Data sheet
- Tripping characteristic - Thermal overload relay TF42-2.3
- Tripping characteristic - Thermal overload relay TF42-16
- Tripping characteristic - Thermal overload relay TF42-13
- Tripping characteristic - Thermal overload relay TF42-10
- Tripping characteristic - Thermal overload relay TF42-1.7
- Tripping characteristic - Thermal overload relay TF42-1.3
- Tripping characteristic - Thermal overload relay TF42-0.17
- Tripping characteristic - Thermal overload relay TF42-1.0
- Tripping characteristic - Thermal overload relay TF42-20
- Tripping characteristic - Thermal overload relay TF42-24
- Tripping characteristic - Thermal overload relay TF42-29
- Tripping characteristic - Thermal overload relay TF42-3.1
- Tripping characteristic - Thermal overload relay TF42-35
- Tripping characteristic - Thermal overload relay TF42-38
- Tripping characteristic - Thermal overload relay TF42-4.2
- Tripping characteristic - Thermal overload relay TF42-5.7
- Tripping characteristic - Thermal overload relay TF42-7.6
- Tripping characteristic - Thermal overload relay TF42-0.55
- Tripping characteristic - Thermal overload relay TF42-0.41
- Tripping characteristic - Thermal overload relay TF42-0.31
- Tripping characteristic - Thermal overload relay TF42-0.23
- Tripping characteristic - Thermal overload relay TF42-0.13
- Thermal tripping limits TF42
- Tripping characteristic - Thermal overload relay TF42-0.74
- Data sheet - Thermal Overload Relay TF42
Declaration of conformity
- EU Declaration of Conformity - TF42, DB42, DRS-F, DRS-F-TF, WRH-F, WRBx, WRBG - Thermal Overload Relay
- EU Declaration of Conformity - TF42-B, DB42, DRS-F - Thermal Overload Relay
- UK Declaration of Conformity - TF42, DB42, DRS-F, DRS-F-TF, WRH-F, WRBx, WRBG - Thermal Overload Relay
- UK Declaration of Conformity - TF42-B, DB42, DRS-F - Thermal Overload Relay
- CCC Declaration of Conformity, Thermal Overload Relay, TF42, TF42B, Made in Germany
- Declaration of Conformity TOL TF42
Drawing
- AF26, AF30, AF38 3-pole contactors with BEY38-4, VEM4 and TF42 thermal overload relay (star-delta)
- AF26, AF30, AF38 3-pole contactors with BEY38-4, VM4 and TF42 thermal overload relay (star-delta)
- Dimension Drawing - TF42 Thermal Overload Relay
- AF09, AF12, AF16 3-pole contactors with TF42 thermal overload relay
- AF09, AF12, AF16 3-pole contactors with TF42 thermal overload relay
- AF09, AF12, AF16 3-pole contactors with TF42 thermal overload relay
- AF26, AF30, AF38 3-pole contactors with TF42 thermal overload relay
- AF26, AF30, AF38 3-pole contactors with TF42 thermal overload relay
- AF26, AF30, AF38 3-pole contactors with TF42 thermal overload relay
Environmental product declaration
Movie
Operating instruction
Reviews
There are no reviews yet.



There are no reviews yet.