SKU: 1SBL157001R1110
AF12-30-10-11
In stock
₴ 2 022,31
The AF12-30-10-11 is a 3 pole – 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 5.5 kW / 400 V AC (AC-3) or 7-1/2 hp / 480 V UL and switching power circuits up to 28 A (AC-1) or 28 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Characteristics
Customs Tariff Number
85364900
Brand
ABB France LP Division Control, ABB France LP Division Control
Minimum Order Quantity
1 piece
Product Net Weight
0.27 kg
Package Level 1 Units
box 1 piece
Package Level 1 Depth / Length
79 mm
Package Level 1 Height
47 mm
Package Level 1 Width
87 mm
Package Level 1 Gross Weight
0.27 kg
Package Level 2 Units
box 27 piece
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
315 mm
Package Level 2 Width
250 mm
Package Level 2 Gross Weight
7.29 kg
Package Level 3 Units
1296 piece
Declaration of Conformity - CE
1SBD250000U1000
RoHS Information
1SBD250000U1000
RoHS Status
Following EU Directive 2011/65/EU
ETIM 7
EC000066 - Power contactor, AC switching
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40/acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20/acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Instructions and Manuals
1SBC101027M6801
Product Net Width
45 mm
Product Net Height
86 mm
Product Net Depth / Length
77 mm
Rated Operational Voltage
Auxiliary Circuit 690 V/Main Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz/Main Circuit 50 / 60 Hz
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V/acc. to UL/CSA 600 V
Wire Stripping Length
Auxiliary Circuit 10 mm/Control Circuit 10 mm/Main Circuit 10 mm
Standards
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
Tightening Torque UL/CSA
Auxiliary Circuit 11 IA/Control Circuit 11 IA/Main Circuit 13 IA
ABS Certificate
ABS_15-GE1349500-PDA_90682247
BV Certificate
BV_2634H24898B0
CB Certificate
CB_SE-96551M1
CQC Certificate
CQC2010010304445624/CQC2020010304298240
cUL Certificate
UL_20180227_E312527_7_1
DNV GL Certificate
DNV-GL_TAE00001AF-3
EAC Certificate
EAC_RU_FRME77B03447
Environmental Information
1SBD250147E1000
GL Certificate
DNV-GL_TAE00001AF-3
LR Certificate
LRS_1300087E1
RINA Certificate
RINA_ELE240318XG
RMRS Certificate
RMRS_1802705280
UL Certificate
UL_20140305-E312527_7_1/UL_20180227_E312527_7_1
Package Level 1 EAN
3471523110311
Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
ETIM 6
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
E-Number (Finland)
3705802
E-Number (Sweden)
3211341
Terminal Type
Screw Terminals
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
CCC Certificate
CCC_2010010304445624
GOST Certificate
GOST_POCCFR.ME77.B07175.pdf
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A/cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
General Use Rating UL/CSA
(600 V AC) 28 A
DNV Certificate
DNV-GL_TAE00001AF-3
KC Certificate
KC_HW02016-15005C
UL Listing Card
E312527
Reviews
Description
- Push-in Spring easy wiring advertisement
- Push-in Spring fast wiring advertisement
- Push-in Spring reliable advertisement
Brochure
- Push-in Spring motor starting solution
- Push-in Spring motor starting solution brochure
- 1SBC100191L0203 - Panorama Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition July 2015
Catalogue
- Motor control and protection for Rolling stock application
- Motor control and protection for Rolling stock application_PDF
- Push-in Spring motor starting solution catalog_PDF 1SBC100212C0203
- 1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition march 2020
- 1SBC101438D0201 3-pole AF contactors for 24 V DC control
- 1SBC101439D0201 4-pole AF contactors for 24 V DC control
- 1SBC100195C0203 - Short-form catalog Motor protection and control: Manual motor starters, contactors and overload relays (PDF) - Edition Nov 2016
Certificate
- CQC Certificate, Auxiliary contacts, CAL4-**, CA4-**, CC4-**, Made in Czech Republic
- CQC Certificate, Auxiliary contacts, CE5-10W0,1,CE5-01W0,1, CE5-10D0,1, CE5-01D0,1,CE5-10W2, CE5-01W2, CE5-10D2, CE5-01D2, Made in Czech Republic
- CB Certificate WA4-.., WA4-96-..- mechanical latch unit for AF09...AF96 contactors and NF contactor relays
- CQC Certificate, Auxiliary contacts, CA4-***,CAT4-*** ,VE4, Made in Poland
- cULus Certificate RV4 / RC4 surge suppressor for AFC09...AFC96 contactors / NFC contactor relays
- CQC Certificate, Contactor, AF*09, AF*12, AF*16, Made in France
- CQC Certificate, Contactor, AF09,AF12,AF16, Made in China
- cULus Certificate BEA..-4, BER..-4(KF), BEY..-4(KF) and LY..-4 accessories for AF09..(K)...AF38..(K) contactors
- CB Certificate CA4 1-pole, CC4 1-pole, CAL4-11 auxiliary contact blocks for AF09...AF96 contactors and NF contactor relays
- CB Certificate CA4 1-pole, CC4 1-pole, CAL4-11 auxiliary contact blocks for AF09...AF96 contactors and NF contactor relays
- CB Certificate WA4-.., WA4-96-..- mechanical latch unit for AF09...AF96 contactors and NF contactor relays
- CB Certificate AF(C)09, AF(C)12, AF(C)16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
- CCC Certificate CA4 4-pole, CAT4-11, VE4 AF accessories with screw, Ring tongue, spring and push-in terminals
- CCC Certificate CA4 and CC4 1-pole, CAL4-11 auxiliary contacts with screw, spring, push-in and RT terminals
- CCC Certificate WA4, WA4-96 - mechanical latching unit for AF09...AF96 contactors and NF contactor relays
- CCC Certificate AF09, AF12, AF16, AF09(Z)B, AF12(Z)B, AF16(Z)B 3 and 4-pole contactors, AFS09, AFS12, AFS16 safety contactors
- UL_20191021-E312527_7_1 - cULus Certificate AF(S)(C)09-..(S)(K)...AF(C)(S)38.(K) 3-pole contactors screw spring and push-in terminals
- cULus Certificate AF(S)(C)09-..(S)(K)...AF(C)(S)38.(K) 3-pole contactors screw spring and push-in terminals
- KC Certificate AF12, AF16 3-pole contactors
- CB Certificate CE5 auxiliary contact blocks for AF09...AF96 contactors and NF contactor relays
- CB Certificate electronic timers TEF4 for AF09...AF96 contactors and NF contactor relays ; TEF5 for A9 ...75, AL9...40 contactors, N and NL contactor relays
- CB Certificate CA4 4-pole and CAT4 auxiliary contact blocks for AF09...AF96 contactors and NF contactor relays
- EAC Certificate for CA(L).., , CAT.., CC(L).., CE(L).., CB.., auxiliary contacts for A, AF, AS contactors and N, NF, NScontactor relays
- Rina Certificate for AF(S)09...AF(S)96 contactors, NF contactor relays and accessories with screw,spring and push-in terminals
- CB Certificate RA4 interface relay - Accessories for AF09...AF96, NF range
- DNV-GL Certificate AF(S)09...96 3-pole & AF09...80 4-pole contactors with screw, spring, push-in terminals
- RMRS Certificate AF(S)09(S)...AF(S)38 3-pole and 4-pole, AF(S)40..96 3-pole contactors with screw, push-in and spring terminals
- RMRS Certificate CA4, CAT4, CAL4-11 - Auxiliary contacts for AF(S)09...AF(S)96, NF ranges, with screw, push-in and spring terminals
- BV Certificate AF09...AF38 3-pole and 4-pole contactors with screw and spring terminals
- BV Certificate CA4, CAT4, CAL4-11 - Accessories for AF09...AF96, NF range with scew and spring terminals
- cULus Certificate CA4, CC4, CAL4, BX4, BX4-CA, BA4 accessories for AF09...AF96 contactors / NF contactor relays
- CCC Certificate electronic timers TEF4 for AF09...AF96 contactors / NF contactor relays ; TEF5 for A9 ...75, AL9...40 contactors / Nand NL contactor relays
- CB Certificate for CE5-01D2, CE5-10D2 auxiliary contacts
- CB Certificate for CE5-01W0.1,CE5-10W0.1 auxiliary contacts
- LCIE Certificate AF09...AF96 contactors, NF contactor relays, CA(L)(T)4 mechanically linked contacts
- LCIE Certificate of conformity for AF09...AF96 contactors and CA(L)(T)4.., mirror contacts acc. IEC60947-4-1
- DNV-GL Certificate AF09...96 3-pole & AF09...80 4-pole contactors
- ClassNK Certificate, AF09...96 3 and 4-pole contactors
- UL Certificate CB5 impulse contact block for AF09..AF96, (T)A(E)9//75, (T)AL9..40 contactors
- cULus Certificate WA4 mechanical latch for AF09...AF96 contactors / NF contactor relays
- cURus Certificate AF09...AF38 3-pole contactors with ring tongue terminals
- CB Certificate RA4-1 - Accessories for AF09...AF96, NF range
- ABS Certificate, Contactor, AF09...96, aux. relays NF, aux. contacts CA(L)4
- cULus Certificate RA4 interface relay for AF09...AF96 contactors / NF contactor relays
- LRS Certificate AF09...AF96 3-pole, AF09...38 4-pole contactors and CA(L)4,CAT4, CC4 auxiliary contacts
- RMRS Certificate AF09(S)...AF38 3-pole and 4-pole, AF40..96 3-pole contactors, screw and spring terminals
- EAC Certificate for CA(L).., , CAT.., CC(L).., CE(L).., CB.., CAF.., CAOVE.., CARB.., EH.. auxiliary contacts
- Rina Certificate for AF09...AF96 contactors, NF contactor relays and accessories, screw and spring terminals
- RMRS Certificate CA4, CAT4, CAL4-11 - Auxiliary contacts for AF09...AF38, NF ranges, with screw and spring terminals
- BV Certificate AF09...AF38 3-pole and 4-pole contactors
- BV Certificate CA4, CAT4, CAL4-11 - Accessories for AF09...AF38, NF range
- cULus Certificate BEA..-4, BER..-4, BEY..-4 and LY..-4 accessories for AF09...AF38 contactors
- cULus Certificate electronic timers TEF4 for AF09...AF38 contactors / NF contactor relays ; TEF5 for A9 ...75, AL9...40 contactors / Nand NL contactor relays
- cULus Certificate VM4, VEM4, BB4 accessories for AF09...AF38 contactors
Data sheet
- Environmental Information LD38-4, LF16-4,LF38-4, LH38-4,LG16-4 - Accessories for AF09...AF38 contactor range
- Environmental Information CA4..RT, CAT4..RT, CAL4-11RT, LDC4RT Accessories for AF09...AF38..RT, NF..RT range
- Environmental Information for AF09(Z)B ... AF38(Z)B 1-stack 3- and 4-pole contactors and NF(Z)B contactor relays
- Environmental Information for AF09(Z)B..RT ... AF38(Z)B..RT 1-stack 3- and 4-pole contactors and NF(Z)B..RT contactor relays
- Environmental Information for AF09, AF12, AF16 1-stack 3-pole and 4-pole Contactors
- Environmental Information for AF09, AF12, AF16 2-stack 3-pole Contactors
Declaration of conformity
- EU Declaration of Conformity AF09 to AF38(Z)B..(K) 3 and 4pole contactors
- EU Declaration of Conformity AF09..LU to AF80..LU 3 and 4pole contactors
- CE declaration for RV4 / RC4 surge suppressor for AFC09...AFC96 contactors / NFC contactor relays
- EU Declaration of Conformity CE5 auxiliary contacts
- EAC Certificate AF09Z...AF38Z-..-..-30 3-pole and AF09Z...AF16Z-..-00-30 4-pole contactors
- EU Declaration of Conformity - BEA.., BER.., BEY.., LY.., LH.., LF.., LG.., LD.. - Accessories for AF09...AF96, AS09..16 contactors
- CCC Declaration of Conformity, Contactor, AF*09, AF*12, AF*16, Made in France
- CCC Declaration of Conformity, Contactor, AF09,AF12,AF16, Made in China
- EU Declaration of Conformity AF09 to AF26(Z)(B)-30..S 3pole contactors
- EU Declaration of Conformity AF09 to AF38(Z)B..RT 3 and 4-pole contactors
- EU Declaration of Conformity AF09... AF96-30-.., AF09...38-30..K 3-pole Contactors
- RoHS2 Declaration of Conformity CA4, CAT4, CAL4-11 - Accessories for AF09...AF96, NF range
- Declaration of Conformity Contactors AF09(Z)B_AF38(Z)B
- Declaration of Conformity contactors AF09_AF96
- ROHS2 Declaration of Conformity WA4-.. - Mechanical latch for AF09...AF38, AF40...96 range
- EC Declaration of Conformity DRAF09 to 16 enclosed motorstarter, FR16AF-12(U) empty enclosure
- EC Declaration of Conformity RA4 - Accessories for AF09...AF96, NF range
- ROHS2 Declaration of Conformity RA4 - Accessories for AF09...AF38, AF40...96 range
- ROHS2 Declaration of Conformity VM4, VM96-4 - Accessories for AF09...AF38, AF40...96 range
- CE Declaration of Conformity AF09, AF12, AF16 3-pole Contactors
- CE Declaration of Conformity AF09...16..-S 3-pole contactors and NF..S contactor relays with spring terminals
- CE Declaration of Conformity CA4..S, CAT4..S, CAL4-11S - Accessories for AF09...AF26(Z)..S, NF(Z)..S range
- CE Declaration of Conformity TEF4-ON, TEF4-OFF - Accessories for AF09...AF38, NF range
- CE Declaration of Conformity TEF4S-ON, TEF4S-OFF - Accessories for AF09...AF26..S, NF..S range
- CE Declaration of Conformity AF09 to AF38(Z)B 3 and 4pole contactors and NF(Z)B contactor relays
- CE Declaration of Conformity AF09 to AF38(Z)B..RT 3 and 4pole contactors and NF(Z)B..RT contactor relays
- CE Declaration of Conformity CA4..RT, CAT4..RT, CAL4-11RT - Accessories for AF09...AF38(Z)B..RT, NF(Z)B..RT range
- RoHS Declaration of Conformity LD38-4, LF16-4,LF38-4, LH38-4,LG16-4 - Accessories for AF09...AF38 contactor range
- RoHS Declaration of Conformity AF09(Z)B...AF38(Z)B 3 and 4-pole contactors and NF(Z)B contactor relays
- RoHS Declaration of Conformity AF09(Z)B..RT...AF38(Z)B..RT 3 and 4-pole contactors and NF(Z)B..RT contactor relays
- RoHS Declaration of Conformity CA4..RT, CAT4..RT, CAL4-11RT, LDC4RT Accessories for AF09...AF38..RT, NF..RT range
- RoHS Declaration of Conformity AF09, AF12, AF16 3-pole Contactors
- RoHS Declaration of Conformity CA4, CAT4, CAL4-11, VEM4 - Accessories for AF09...AF38, NF range
- CE Declaration of Conformity CA4, CAT4, CAL4-11, VEM4 - Accessories for AF09...AF38, NF range
Drawing
- BEA16-4K + AF09...AF16..K + MS132..K DOL starter with push-in terminals
- BEA38-4K + AF26...AF38..K + MS132..K DOL starter with push-in terminals
- 1-pole CE5 auxiliary contact block with AF09...AF96 3- and 4-pole contactors and NF contactor relays
- BDT4 test block with AF09...AF96 3- and 4-pole contactors and NF contactor relays
- RA4 interface relay with AF09...AF96 3- and 4-pole contactors and NF contactor relays
- BER16-4 connection set for AF09...AF16 reversing contactors
- BEY16-4 connection set for AF09...AF16 star-delta contactors
- BX4 protective cover with AF09...AF38 contactors and NF contactor relays
- CAL4 auxiliary contact block with AF09...AF38 contactors and NF contactor relays
- LH38-4 terminal connecting strip for AF09, AF12, AF16 contactors
- LF16-4 terminal connecting strip for AF09, AF12, AF16 contactors
- LG16-4 terminal connecting strip for AF09, AF12, AF16 contactors
- AF/AFS09, AF12, AF16Z-30-22-30 contactors and 8-pole NFZ..E-30 contactor relays with 24VDC coil
- AF09, AF12, AF16..-30-10/01-30 contactors and 4-pole NF..E-30 contactor relays with 24VDC coil
- 1-pole CA4..K, auxiliary contact block with AF09...AF38..K 3-pole contactors and NF..K contactor relays with push-in terminals
- 2-pole CAL4..K aux. contact block with AF09...AF38..-K 3-pole contactors or NF..K contactor relays, with push-in terminals
- 4-pole CA4..K aux. contact block with AF09...AF38..-K 3-pole contactors or NF..K contactor relays, with push-in terminals
- AF09.K, AF12.K, AF16..-30-10/01K contactors; 4-pole NF..K contactor relays with push-in terminals
- AF09.K, AF12.K, AF16..-30-32K contactors; 8-pole NF..K contactor relays with push-in terminals
- AF09.S, AF12.S, AF16..-30-10/01S contactors; 4-pole NF.S contactor relays with spring terminals
- AF09, AF12, AF16..-30-10/01 contactors; 4-pole NF contactor relays
- AF09, AF12, AF16..-30-10/01 contactors; 4-pole NF contactor relays
- AF09, AF12, AF16..-30-10/01 contactors; 4-pole NF contactor relays
- 4-pole CA4 aux. contact block with AF09...AF16 3-pole contactors or 4-pole NF contactor relays; AF09...AF16..-30-22 3-pole contactors; 8-pole NF contactor relays
- 4-pole CA4 aux. contact block with AF09...AF16 3-pole contactors or 4-pole NF contactor relays; AF09...AF16..-30-22 3-pole contactors; 8-pole NF contactor relays
- 4-pole CA4 aux. contact block with AF09...AF16 3-pole contactors or 4-pole NF contactor relays; AF09...AF16..-30-22 3-pole contactors; 8-pole NF contactor relays
- AF09, AF12, AF16 3-pole contactors with TF42 thermal overload relay
- AF09, AF12, AF16 3-pole contactors with TF42 thermal overload relay
- AF09, AF12, AF16 3-pole contactors with TF42 thermal overload relay
- AF09, AF12, AF16 3-pole contactors with EF19 electronic overload relay
- AF09, AF12, AF16 3-pole contactors with EF19 electronic overload relay
- AF09, AF12, AF16 3-pole contactors with EF19 electronic overload relay
- WB75-A mechanical latching unit with AF09...AF16 contactors or 4-pole NF contactor relays
- WB75-A mechanical latching unit with AF09...AF16 contactors or 4-pole NF contactor relays
- WB75-A mechanical latching unit with AF09...AF16 contactors or 4-pole NF contactor relays
- dimensions - WA4 mechanical latch with NF(Z) contactor relay, AF09(Z)...AF96 3- and 4pole contactors
- AF09.S, AF12.S, AF16..-30-10/01S contactors; 4-pole NF.S contactor relays with spring terminals
- AF09.S, AF12.S, AF16..-30-10/01S contactors; 4-pole NF.S contactor relays with spring terminals
- 4-pole CA4.S aux. contact block with AF09...AF16.S 3-pole contactors or 4-pole NF.S contactor relays; AF09...AF16..-30-22S 3-pole contactors; 8-pole NF.S contactor relays with spring terminals
- 4-pole CA4.S aux. contact block with AF09...AF16.S 3-pole contactors or 4-pole NF.S contactor relays; AF09...AF16..-30-22S 3-pole contactors; 8-pole NF.S contactor relays with spring terminals
- 4-pole CA4.S aux. contact block with AF09...AF16.S 3-pole contactors or 4-pole NF.S contactor relays; AF09...AF16..-30-22S 3-pole contactors; 8-pole NF.S contactor relays with spring terminals
- AF09..RT, AF12..RT, AF16..RT 3 and 4-pole contactors and contactor relays NF..RT with ring tongue terminals
- 4-pole CA4..RT aux. contact block with AF09...AF16-..RT 3 and 4-pole contactors and NF..RT contactor relays or 8-pole NF..RT contactor relays with ring tongue terminals
- 2-pole CAL4..RT aux. contact block with AF09...AF38..-RT 3 and 4-pole contactors or NF..RT contactor relays, with ring tongue terminals
- 2-pole CA4..RT aux. contact block with AF09...AF16..-RT 3 and 4-pole contactors with ring tongue terminals
- CAT4 auxiliary contact block with AF09...AF65 contactors and NF contactor relays
- 1-pole CB5-10 impulse contact block with AF09...AF96 3- and 4pole contactors
- 1-pole CB5-01 impulse contact block with AF09...AF96 3- and 4pole contactors
- 1-pole CA4, CC4 auxiliary contact block with AF09...AF96 3- and 4pole contactors and NF contactor relays
- TEF4, TEF4S electronic timer with AF09(S)...AF16(S) contactors and NF..(S) contactor relays with screw and spring terminals
Environmental product declaration
Leaflet
- Push-in Spring brochure
- Push-in Spring solution
- Push-in Spring motor starting solution customer flyer
Movie
- Push-in Spring motor starting solution Teaser Video
- Push-in Spring motor starting solution concept video
- Push-in Spring Teaser video
Operating instruction
- Installation instructions AF(C)09...38(Z)(B) Contactors, NF(C)(Z)(B)22...80E Contactor relays and CA4, CAL4, CAT4, CC4, LDC4 Accessories
- Installation instructions AF(C)09...38(Z)(B)..K Contactors, NF(C)(Z)(B)..K Contactor relays and CA4..K, CAL4..K, LDC4K Accessories
- Installation instructions AF09...38(Z)B-..RT Contactors, NF(Z)B..ERT Contactor relays and CA4..RT, CAL4..RT, CAT4..RT, LDC4RT Accessories
- Installation instructions AF09...38Z-..-..-30 Contactors, NFZ..E-30 Contactor relays and CA4, CAL4, CC4, LDC4 Accessories
- Installation instructions AF09..26(Z)..S/AF09..26(Z)B..S Contactors, NF(Z)..S/NF(Z)B22..80ES Contactor relays and CA4..S, CAL4..S, CAT4..S, LDC4S Accessories
- Installation instructions AFS09(Z)...96 Contactors, CAL4, LDC4 Accessories
- Operating instruction BEY16-4KF, BEY38-4KF Star-Delta connection set for AF09..K...AF38..K contactors with Push-In Spring Terminals
- Operating instruction BER16-4KF, BER38-4KF connection sets for AF09..K...AF38..K reversing contactors with Push-In Spring Terminals
- Operating instruction BEA16-4K, BEA38-4K connecting link
- Operating instruction TEF4, TEF4S electronic timers for AF09...AF96 contactors and NF contactor relays
- Operating instruction BDT4 test block for NF, AF09...AF96, NS(L), AS(L)09...16 contactors
- Operating instruction VEM4, VM4 interlocks for AF(S)09...AF(S)38 contactors
- Operating instruction BER16-4, BER38-4 connection sets for AF(S)09...AF(S)38 reversing contactors
- Operating instruction BEY16-4, BEY38-4 connection sets for AF(S)09...AF(S)38 star-delta starters
- Operating instruction AF09(Z)B...AF38(Z)B contactors, NF(Z)B contactor relays and CA4, CAL4, CAT4, CC4 accessories
- Operating instruction BEA16-4, BEA26-4, BEA38-4 connecting links for AF09...AF38 contactors
- Operating instruction WA4 mechanical latch for AF09...AF96 contactors and NF contactor relays
- Operating instruction RA4 interface relay for AF09...AF96 contactors and NF contactor relays
- Operating instruction CA4, CAL4, CAT4, CC4, LDC4 accessories for AF09...AF96 contactors, NF contactor relays
White paper
Reviews
There are no reviews yet.